Look at the term. Do you know what it means? Tap the card. 109 terms from the lessons.

0 of 109 terms known

All terms by topic

Ozone depletion and refrigerant types

Lesson: EPA 608 Core: ozone depletion and refrigerant types (CFC, HCFC, HFC)

Stratosphere:
The atmosphere layer from about 10 to 50 km up; it holds most of the ozone.
Troposphere:
The lowest layer of the atmosphere, where weather happens.
UVB:
Ultraviolet light from the sun that ozone mostly absorbs; linked to skin cancer and cataracts.
CFC:
Chlorofluorocarbon, such as R-12; contains chlorine and has the highest ozone damage.
HCFC:
Hydrochlorofluorocarbon, such as R-22; contains chlorine but damages ozone much less than a CFC.
HFC:
Hydrofluorocarbon, such as R-134a or R-410A; no chlorine, so zero ozone depletion.
ODP:
Ozone depletion potential: harm to ozone compared with CFC-11 (1.0).
GWP:
Global warming potential: warming effect compared with carbon dioxide.
Clean Air Act, Montreal Protocol and Section 608 rules

Lesson: EPA 608 Core: Clean Air Act, Montreal Protocol and Section 608 rules

Montreal Protocol:
International treaty phasing out ozone-depleting substances; signed by the U.S. in 1987.
Venting prohibition:
Ban on knowingly releasing refrigerant during service, repair or disposal.
De minimis release:
A very small loss during good-faith recovery that follows the rules; not a violation.
Sales restriction:
Only certified technicians, or employers of one, may buy refrigerant (with narrow exceptions).
Final processor:
The last link before final disposal, for example a scrap recycler or a landfill.
Leak rate:
The share of the full charge an appliance would lose over 12 months at its current loss rate.
Substitute refrigerants, oils and the HFC phase-down

Lesson: EPA 608 Core: substitute refrigerants, oils, blends and the HFC phasedown

Substitute:
A refrigerant used in place of a CFC or HCFC, such as an HFC, HFO, hydrocarbon, ammonia or CO2.
Drop-in:
A replacement that needs no system changes; EPA says there are none.
Retrofit:
Converting an appliance to a different refrigerant, often with new oil and seals.
Ester oil:
Lubricant EPA pairs with the HFC R-134a.
Alkylbenzene:
Lubricant EPA pairs with HCFCs such as R-22.
Fractionation:
Parts of a refrigerant blend leaking at different rates, changing the mix left behind.
AIM Act:
2020 U.S. law that phases down HFCs and sets rules on leaks and reclaim.
Kigali Amendment:
Addition to the Montreal Protocol that phases down HFCs worldwide.
Refrigeration cycle, gauges and leak detection

Lesson: EPA 608 Core: the refrigeration cycle, pressure classes and leak checks

Evaporator:
Where liquid refrigerant boils to vapor and absorbs heat; the cooling coil.
Condenser:
Where hot refrigerant gas gives off heat and turns into liquid.
Compressor:
Raises the pressure of refrigerant vapor and moves it round the system.
Receiver:
A vessel that stores liquid refrigerant.
Suction accumulator:
Keeps liquid refrigerant out of the compressor suction.
psia:
Pounds per square inch absolute, the scale EPA uses for pressure classes.
Low-pressure appliance:
Uses a refrigerant below 45 psia at 104 °F, such as R-123.
High-pressure appliance:
Uses a refrigerant between 170 and 355 psia at 104 °F, such as R-410A.
Recover, recycle, reclaim and evacuation

Lesson: EPA 608 Core: recover, recycle, reclaim and evacuation basics

Recover:
Remove refrigerant and store it in an outside container, with no testing or cleaning required.
Recycle:
Clean refrigerant with oil separation and filter-driers for reuse by the same owner.
Reclaim:
Reprocess refrigerant to AHRI 700-2016 purity and verify it by analysis.
Certified reclaimer:
A business certified by EPA to reclaim refrigerant for sale to new owners.
Self-contained recovery equipment:
A recovery machine that works without the appliance's components.
System-dependent recovery equipment:
Recovery equipment that relies on the appliance's own parts; limited to appliances of 15 pounds or less unless permanently attached.
Dehydration evacuation:
Pulling a vacuum at the end of service to remove air and moisture.
AHRI Standard 700-2016:
The refrigerant purity standard behind EPA's reclaim specifications.
Safety, cylinders and shipping

Lesson: EPA 608 Core: refrigerant safety, cylinders, nitrogen and shipping

Asphyxia:
Suffocation; can happen when heavy refrigerant vapor displaces oxygen.
Cardiac arrhythmia:
An irregular heartbeat; a possible effect of breathing high refrigerant levels.
Frostbite:
Freezing injury to skin or eyes from contact with liquid refrigerant.
SCBA:
Self-contained breathing apparatus, used in extreme exposure situations.
Recovery cylinder:
A reusable, DOT-approved cylinder coded yellow and gray.
Disposable cylinder:
A one-trip cylinder of new refrigerant; never refilled.
Heel:
The refrigerant left in a used cylinder; the rule calls it the heel or residue.
Relief valve:
A valve that opens to stop pressure going too high, used with nitrogen regulators.
Small appliances: definition and recovery requirements

Lesson: EPA 608 Type I: what counts as a small appliance and how much refrigerant to recover

Small appliance:
An appliance built, charged and sealed in a factory with 5 pounds or less of refrigerant.
Process stub:
A piece of tubing that gives access to the refrigerant and is resealed after service.
November 15, 1993:
The recovery equipment manufacture date that decides whether 80 or 90 percent applies.
4 inches Hg vacuum:
Vacuum level that meets the small-appliance recovery rule in every case.
Final processor:
Whoever takes the last step in disposal, for example a scrap yard or landfill.
De minimis release:
A tiny release during good faith recovery with the required practices; not a violation.
Mail-in Type I:
Open-book Type I test that passes at 84 percent and does not count toward Universal.
Small appliances: recovery techniques

Lesson: EPA 608 Type I recovery techniques: passive recovery, access valves and the test stand

System-dependent (passive) recovery:
Recovery that relies on the appliance's own parts, such as its compressor.
Self-contained recovery:
Recovery equipment that works without help from the appliance.
Solderless access fitting:
A bolt-on fitting used to reach the refrigerant; remove it after service.
Noncondensables:
Gases such as air that do not turn to liquid in the system and raise pressure.
Recover:
Take refrigerant out and store it in an outside container, in any condition.
Recycle:
Clean refrigerant for reuse by the same owner, short of full reclaim purity.
Recovery efficiency:
Recovered amount divided by recoverable amount, times 100.
Small appliances: safety and refrigerants

Lesson: EPA 608 Type I safety: refrigerant breakdown by heat and flammable R-600a and R-290

Phosgene:
Highly toxic gas that can form when CFC or HCFC refrigerant meets a flame or hot metal.
Thermal decomposition:
Breakdown of a refrigerant into other chemicals caused by high heat.
R-600a (isobutane):
Flammable hydrocarbon refrigerant common in new household refrigerators.
R-290 (propane):
Flammable hydrocarbon refrigerant used in some new refrigerators, coolers and room air conditioners.
Lower flammability limit (LFL):
The lowest concentration in air at which a gas can burn.
Spark-proof tools:
Tools that will not create sparks; EPA's use conditions call for them on hydrocarbon units.
Class B extinguisher:
Fire extinguisher type for flammable liquids and gases.
High-pressure: leak detection and leak repair

Lesson: EPA 608 Type II: finding leaks and the leak repair rules

Leak rate:
Percent of the full charge that would be lost in a year at the current rate of loss.
Full charge:
The refrigerant amount the appliance needs to run normally.
Trigger rate:
The leak rate above which repair is required: 20, 30 or 10 percent.
Industrial process refrigeration:
Systems tied to industrial processes, plus ice rinks and industrial ice machines.
Initial verification test:
A leak test right after the repair, before refrigerant goes back in.
Follow-up verification test:
A second check within 10 days, once the system runs normally.
Seasonal variance:
Refrigerant removed for a season and later returned in the same or a smaller amount within 12 months.
High-pressure: recovery requirements and techniques

Lesson: EPA 608 Type II: required evacuation levels and recovery techniques

High-pressure appliance:
Uses a refrigerant with a liquid saturation pressure of 170 to 355 psia at 104 °F, such as R-410A or R-22.
Table 1:
The chart in 40 CFR 82.156 that sets the vacuum level to reach before opening or disposing of an appliance.
Major repair:
Removing the compressor, condenser, evaporator or an auxiliary coil, or leaving more than 4 sq in open for over 15 minutes.
System receiver:
The isolated part or vessel of an appliance that holds the charge while another part is serviced.
System-dependent recovery:
Recovery that relies on the appliance's own parts, such as its compressor; limited to systems of 15 pounds or less.
Recycle:
Clean refrigerant, for example with filter-driers, for reuse by the same owner.
Reclaim:
Reprocess refrigerant to the AHRI 700 purity standard and verify it; needed before it changes owner.
High-pressure: safety, charging and disposal

Lesson: EPA 608 Type II: safety, charging and disposal

SCBA:
Self-contained breathing apparatus: a breathing set with its own air supply, for extreme cases such as low oxygen.
Oxygen deprivation:
Not enough oxygen to breathe, which can happen when leaking refrigerant displaces air in a closed room.
ASHRAE Standard 15:
The safety standard for refrigeration systems that sets equipment room requirements, such as sensors.
Recovery cylinder:
A reusable, DOT-approved cylinder, gray with a yellow top, for holding recovered refrigerant.
Disposable cylinder:
A one-trip cylinder for new refrigerant; it must never be refilled.
Heel:
The refrigerant left in a cylinder after normal use.
psia:
Pounds per square inch absolute: the gauge reading (psig) plus 14.7.
Low-pressure: leak detection and leak repair

Lesson: Type III leak testing and leak repair for low-pressure chillers

Low-pressure appliance:
Uses a refrigerant whose liquid saturation pressure is under 45 psia at 104°F, such as R-11 or R-123.
Purge unit:
Device on a low-pressure chiller that removes air and water; heavy purge running points to a leak.
Rupture disc:
Safety disc on the evaporator that protects the shell; on many chillers it bursts at about 15 psig.
Trigger leak rate:
Yearly leak rate above which repairs are required: 10%, 20% or 30% depending on the appliance type.
Initial verification test:
Leak test right after a repair, before refrigerant goes back in when the system was evacuated.
Follow-up verification test:
Second check within 10 days, once the chiller runs normally, that the repair held.
Chronically leaking appliance:
One that loses 125% or more of its full charge in a calendar year; it must be reported to EPA.
Low-pressure: recovery, recharging and evacuation

Lesson: Type III recovery, evacuation and recharging of low-pressure chillers

25 mm Hg absolute:
Required recovery level for every low-pressure appliance, about 29 inches of mercury vacuum.
Major repair:
Removes the compressor, condenser, evaporator or auxiliary coil, or leaves over 4 sq in open for over 15 minutes.
0 psig:
Atmospheric pressure; the highest pressure allowed when opening a low-pressure chiller for a non-major repair.
Controlled hot water:
Warm water run through the tubes to raise refrigerant pressure without adding gas.
Evaporator charging valve:
The usual point for charging refrigerant into a centrifugal chiller.
Pump-out unit:
Recovery equipment permanently attached to a chiller; the only system-dependent equipment allowed over 15 lb.
Reclaim:
Reprocess refrigerant to the AHRI 700 purity standard; needed when recovered refrigerant changes owner.
Low-pressure: safety and purge units

Lesson: Type III safety: machinery rooms, purge units and low-pressure refrigerants

ASHRAE Standard 15:
Safety standard for refrigeration systems, including machinery room sensors, alarms and ventilation.
Oxygen-deprivation sensor:
Monitor that warns when refrigerant has pushed out breathable air; EPA's topic list ties it to all refrigerants.
Refrigerant sensor (detector):
Continuous monitor for refrigerant in the room; required for R-123 under ASHRAE 15.
Non-condensables:
Gases such as air that do not turn to liquid in the condenser and raise head pressure.
Purge unit:
Device that removes non-condensables and water from a low-pressure chiller.
Asphyxiation:
Suffocation when refrigerant vapor displaces the oxygen in a room.
Saturation pressure:
Pressure of a refrigerant with liquid and vapor together at a given temperature; it rises as temperature rises.